Changes for page **Crestron Zūm Wired and SHOWRUNNER™
Last modified by Alexander Mott on 2023/12/08 18:49
From version 16.1
edited by Alexander Mott
on 2023/03/28 16:43
on 2023/03/28 16:43
Change comment:
There is no comment for this version
To version 20.1
edited by Alexander Mott
on 2023/03/28 19:05
on 2023/03/28 19:05
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -59,8 +59,13 @@ 59 59 60 60 = Feature Comparison Tables = 61 61 62 -== SHOWRUNNER == 62 +== SHOWRUNNER™ vs Default Program vs Standalone == 63 63 64 +(% class="box errormessage" %) 65 +((( 66 +need to verify information is up to date for this section 67 +))) 68 + 64 64 The below table compares some SHOWRUNNER exclusive features against networked systems using the default program and standalone systems using Zūm App mode. 65 65 66 66 |=Feature|=((( ... ... @@ -78,7 +78,7 @@ 78 78 ))) 79 79 |(% colspan="4" %)**Hardware Requirements** 80 80 |Requires ZUMNET-JBOX-*|Y|Y|N 81 -|Requires 3 or 4-Series Control System|Y|Y (Requires ZUM-HUB4)|N 86 +|Requires 3 or 4-Series Control System|Y (Can use a number of different 3 and 4-Series processors)|Y (Requires ZUM-HUB4)|N 82 82 |Requires Physical Presence in Room to Change Scenes|N|TBD|Y 83 83 |Maximum Rooms|TBD|1000|N/A 84 84 |(% colspan="4" %)**User Interfaces** ... ... @@ -176,6 +176,19 @@ 176 176 |ZWMS (Zum Wired Master/Slave Mode)|MASTER|MASTER|MASTER or SLAVE 177 177 |ZWMODE|CNET or ZUM (ZUM Support Pending official release from Crestron)|ZUM|ZUM 178 178 184 +=== Caveats === 185 +* Consult Chief Integrations to verify sequence of operations if there are any concerns. 186 +* Additional caveats: 187 +** --Occupancy status is not reported to ShowRunner when ZUMNET/ZUMLINK JBOXs come online. This has been acknowledged as a bug by Crestron in firmware v1.001.054 and v1.00.009 and is pending a fix from Crestron.-- Fixed in 1.02.010 firmware and Device Database 200.150.002, ShowRunner 3.016 has been updated with these fixes from Crestron. 188 +** --Raw Occupancy reporting does not work. A delay of 5 seconds to 5 minutes between sensor vacancy and reported vacancy to ShowRunner. ShowRunner attempts to set 30 seconds (v3.003 to v3.009) or 5 seconds (v3.010 and later) but it is not always honored. This has been acknowledged as a bug by Crestron in firmware v1.001.054 and v1.00.009 and is pending a fix from Crestron.-- Fixed in 1.02.010 firmware and Device Database 200.150.002, ShowRunner 3.016 has been updated with these fixes from Crestron. 189 +** Cresnet Discovery is not working on ZUMNET-JBOXs. Crestron has acknowledged a fix has been sent to QE. Discovery must be fixed before ShowRunner can auto-discover hardware. 190 +=== FAQ: === 191 +* I want to have a single connection to the building and have all of my Crestron devices on the Control Subnet (same topology as a ZUM-FLOOR-HUB) and use ShowRunner™ Total Control? 192 +//Use a CP4N in lieu of the ZUM-FLOOR-HUB. A DIN-AP4 is not required. Crestron can supply a DIN-EN-6X18 with CEN-SW-POE-16 and CP4N racked in a 2RU mount plus 3 DIN rails. [[See Design Details.>>doc:Design Guide.Hardware Design Guide.Crestron Zūm Wired.Design to co-locate a CP4N and CEN-SWPOE-16 in the Same DIN-EN Cabinet.WebHome]]// 193 +* Do I need a Crestron BACnet license when using ShowRunner for BACnet integration? 194 +//If over 50 BACnet points are needed then a license (SW-3SERIES-BACNET-50+) will be needed for each Crestron processor that will provide BACnet points to the BMS.// 195 + 196 + 179 179 == Out-of-the-Box vs App vs Default Program vs Custom Program == 180 180 181 181 Below is a Feature Comparison Table taken from the v3.05.02 Zūm Wired firmware release notes.