Last modified by Alexander Mott on 2023/12/08 18:49

From version 15.1
edited by Alexander Mott
on 2023/03/28 16:22
Change comment: There is no comment for this version
To version 18.1
edited by Alexander Mott
on 2023/03/28 16:47
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -57,10 +57,134 @@
57 57  
58 58  SHOWRUNNER™
59 59  
60 -= Feature Comparison Table =
60 += Feature Comparison Tables =
61 61  
62 -Below is a Feature Comparison Table taken from the v3.05.02 Zūm Wired firmware release notes.
62 +== SHOWRUNNER™ vs Default Program vs Standalone ==
63 63  
64 +(% class="box errormessage" %)
65 +(((
66 +need to update this section
67 +)))
68 +
69 +The below table compares some SHOWRUNNER exclusive features against networked systems using the default program and standalone systems using Zūm App mode.
70 +
71 +|=Feature|=(((
72 +**Networked**
73 +
74 +**(**SHOWRUNNER™**)**
75 +)))|=(((
76 +**Networked**
77 +
78 +**(HUB4)**
79 +)))|=(((
80 +**Zūm App**
81 +
82 +**(Standalone)**
83 +)))
84 +|(% colspan="4" %)**Hardware Requirements**
85 +|Requires ZUMNET-JBOX-*|Y|Y|N
86 +|Requires 3 or 4-Series Control System|Y (Can use a number of different 3 and 4-Series processors)|Y (Requires ZUM-HUB4)|N
87 +|Requires Physical Presence in Room to Change Scenes|N|TBD|Y
88 +|Maximum Rooms|TBD|1000|N/A
89 +|(% colspan="4" %)**User Interfaces**
90 +|Web Browser|(((
91 +Crestron SmartGraphics XPanel
92 +HTML5 UI
93 +)))|HTML5 UI|N
94 +|iOS/Android|Y, Crestron App (Paid Upgrade) or HTML5 UI (Device Web Browser)|N|Y*
95 +|Touchscreens (Crestron TSW series)|Y|N|N
96 +|(% colspan="4" %)**Features**
97 +|Scene Recall|Y|Y|Y
98 +|Override Fade Time for Scene Recall|Y|TBD|TBD
99 +|Scene Save|Y|TBD|Y
100 +|Load Control|Y|TBD|Y
101 +|Demand Response|Y|Y|N
102 +|Enable/Disable Occupancy|Y|Y|Y
103 +|Override Occupancy Logic|Y|TBD|N
104 +|Override|Y|TBD|N/A
105 +|Plug Load On/Off|Y|Y|By Hardware
106 +|Integration with Non-Zūm Crestron Hardware|Y|N|N
107 +|Custom Zūm Keypad Programming|Y|TBD|Y, within the limits of the hardware
108 +|New Feature Release Cycle|Aggressive|6-12 months|6-12 months
109 +|Room Organization|(((
110 +Organize According to Defined Nodes, multiple levels
111 +Categorization to Filter by Tag
112 +)))|Category/Room|(((
113 +N/A
114 +)))
115 +|Room Discovery|Automatic Discovery of ZUMNET and ZUMLINK devices (Pending)|Automatic Discovery of ZUMNET and ZUMLINK devices|N/A
116 +|Network Topology|(((
117 +* Flat
118 +* Single Handoff to LAN w/ Control Subnet
119 +(Requires CP4N/AV4/PRO4)
120 +)))|Single Handoff to LAN w/ Control Subnet|N/A
121 +|Network Addressing|(((
122 +* Manual
123 +* Customer (DHCP or Manual)
124 +* DHCP: Control Subnet (Requires CP4N/AV4/PRO4)
125 +)))|Control Subnet|N/A
126 +|Firmware Updates|PUF Tool
127 +Automatic Support on Roadmap|Automatic, Internet Connection Required|N/A
128 +|Floorplans|Y|N|N/A
129 +|(% colspan="4" %)**Calendar/Scheduling**
130 +|Logic Type|Event Driven
131 +Profile Support (Under Development)|Pattern assigned to Category|N/A
132 +|Astronomical Clock|Y|Y, Per Category|N/A
133 +|Holidays|Pattern|Hard Coded|N/A
134 +|Custom Patterns|Y, Advanced Scheduler License|N|N/A
135 +|(% colspan="4" %)**Integrations**
136 +|A/V Integration: API|Y|Limited|N/A
137 +|A/V Integration: Crestron EISC|Y|N|N/A
138 +|A/V Integration: RS-232|Y|TBD|N/A
139 +|BACNET|Y, SHOWRUNNER™ and Crestron Licenses Needed|Y|N/A
140 +|BACNET Features|(((
141 +Per Area Status:
142 +Active Scene
143 +Occupied
144 +Occupancy Enabled
145 +Individual Load Level
146 +Photocell Level (per Photocell)
147 +Plug Loads Enabled
148 +System:
149 +Demand Response Enabled
150 +System Wide Override (Panic/Emergency)
151 +~* More Features added upon request
152 +)))|(((
153 +Per Room Status:
154 +Online
155 +On
156 +Occupied
157 +Daylighting Active
158 +Device Battery is Low
159 +Plug Loads Enabled
160 +Occupancy Sensor Enabled
161 +Current Daylight Level
162 +Active Scene
163 +\\System:
164 +Demand Response Enabled
165 +)))|N/A
166 +|BACNET Settings Scope
167 +(What Points are Exposed)|Per Area|Global|N/A
168 +|BACNET Points Supported|Depends on Crestron License and Hardware|1000|N/A
169 +|Crestron Fusion|Y|N|N/A
170 +|Export to Zūm Floor Hub|Y, Licensed|N/A|N/A
171 +|GLPAC|Y|N|N/A
172 +|System to System Link|Y|N|N/A
173 +|Minimum ZUM-NET Firmware|(((
174 +CNET Mode: ZUM-WIRED 1.02.10 puf
175 +ZUM Mode: ZUM-WIRED 1.xx.xxx puf (Pending)
176 +)))|See Crestron, expected to be v1.01|See Crestron, expected to be v1.01
177 +|Minimum SHOWRUNNER™ Version|(((
178 +CNET Mode: 3.016
179 +ZUM Mode: TBD
180 +)))|N/A|N/A
181 +|ZWMS (Zum Wired Master/Slave Mode)|MASTER|MASTER|MASTER or SLAVE
182 +|ZWMODE|CNET or ZUM (ZUM Support Pending official release from Crestron)|ZUM|ZUM
183 +
184 +== Out-of-the-Box vs App vs Default Program vs Custom Program ==
185 +
186 +Below is a Feature Comparison Table taken from the v3.05.02 Zūm Wired firmware release notes.
187 +
64 64  (% class="table-condensed" %)
65 65  |**Feature**|**Out of the Box Functionality**|(((
66 66  **Zūm App**