Summary

Details

Page properties
Content
... ... @@ -34,6 +34,7 @@
34 34  == Ease of Start-Up and Documentation ==
35 35  
36 36  Every SHOWRUNNER™ job comes with a number of Chief Tools™ to simplify the start-up process and enable Agents and Technicians to for networked Zūm Wired systems. These tools include:
37 +
37 37  * SRTakeoff spreadsheet provides the Technician with one location to view device addresses, record serial numbers, and track any issues discovered during start-up
38 38  * Zūm Wired Load Script generator enables technicians to easily create load scripts to streamline necessary configuration tasks based on the DeviceSummary.txt generated by Toolbox
39 39  
... ... @@ -56,7 +56,186 @@
56 56  
57 57  SHOWRUNNER™
58 58  
59 -= Feature Comparison Table =
60 += Feature Comparison Tables =
60 60  
61 -Lorem
62 +== SHOWRUNNER™ vs Default Program vs Standalone ==
63 +
64 +(% class="box errormessage" %)
65 +(((
66 +need to verify information is up to date for this section
62 62  )))
68 +
69 +The below table compares some SHOWRUNNER exclusive features against networked systems using the default program and standalone systems using Zūm App mode.
70 +
71 +|=Feature|=(((
72 +**Networked**
73 +
74 +**(**SHOWRUNNER™**)**
75 +)))|=(((
76 +**Networked**
77 +
78 +**(HUB4)**
79 +)))|=(((
80 +**Zūm App**
81 +
82 +**(Standalone)**
83 +)))
84 +|(% colspan="4" %)**Hardware Requirements**
85 +|Requires ZUMNET-JBOX-*|Y|Y|N
86 +|Requires 3 or 4-Series Control System|Y (Can use a number of different 3 and 4-Series processors)|Y (Requires ZUM-HUB4)|N
87 +|Requires Physical Presence in Room to Change Scenes|N|TBD|Y
88 +|Maximum Rooms|TBD|1000|N/A
89 +|(% colspan="4" %)**User Interfaces**
90 +|Web Browser|(((
91 +Crestron SmartGraphics XPanel
92 +HTML5 UI
93 +)))|HTML5 UI|N
94 +|iOS/Android|Y, Crestron App (Paid Upgrade) or HTML5 UI (Device Web Browser)|N|Y*
95 +|Touchscreens (Crestron TSW series)|Y|N|N
96 +|(% colspan="4" %)**Features**
97 +|Scene Recall|Y|Y|Y
98 +|Override Fade Time for Scene Recall|Y|TBD|TBD
99 +|Scene Save|Y|TBD|Y
100 +|Load Control|Y|TBD|Y
101 +|Demand Response|Y|Y|N
102 +|Enable/Disable Occupancy|Y|Y|Y
103 +|Override Occupancy Logic|Y|TBD|N
104 +|Override|Y|TBD|N/A
105 +|Plug Load On/Off|Y|Y|By Hardware
106 +|Integration with Non-Zūm Crestron Hardware|Y|N|N
107 +|Custom Zūm Keypad Programming|Y|TBD|Y, within the limits of the hardware
108 +|New Feature Release Cycle|Aggressive|6-12 months|6-12 months
109 +|Room Organization|(((
110 +Organize According to Defined Nodes, multiple levels
111 +Categorization to Filter by Tag
112 +)))|Category/Room|(((
113 +N/A
114 +)))
115 +|Room Discovery|Automatic Discovery of ZUMNET and ZUMLINK devices (Pending)|Automatic Discovery of ZUMNET and ZUMLINK devices|N/A
116 +|Network Topology|(((
117 +* Flat
118 +* Single Handoff to LAN w/ Control Subnet
119 +(Requires CP4N/AV4/PRO4)
120 +)))|Single Handoff to LAN w/ Control Subnet|N/A
121 +|Network Addressing|(((
122 +* Manual
123 +* Customer (DHCP or Manual)
124 +* DHCP: Control Subnet (Requires CP4N/AV4/PRO4)
125 +)))|Control Subnet|N/A
126 +|Firmware Updates|PUF Tool
127 +Automatic Support on Roadmap|Automatic, Internet Connection Required|N/A
128 +|Floorplans|Y|N|N/A
129 +|(% colspan="4" %)**Calendar/Scheduling**
130 +|Logic Type|Event Driven
131 +Profile Support (Under Development)|Pattern assigned to Category|N/A
132 +|Astronomical Clock|Y|Y, Per Category|N/A
133 +|Holidays|Pattern|Hard Coded|N/A
134 +|Custom Patterns|Y, Advanced Scheduler License|N|N/A
135 +|(% colspan="4" %)**Integrations**
136 +|A/V Integration: API|Y|Limited|N/A
137 +|A/V Integration: Crestron EISC|Y|N|N/A
138 +|A/V Integration: RS-232|Y|TBD|N/A
139 +|BACNET|Y, SHOWRUNNER™ and Crestron Licenses Needed|Y|N/A
140 +|BACNET Features|(((
141 +Per Area Status:
142 +Active Scene
143 +Occupied
144 +Occupancy Enabled
145 +Individual Load Level
146 +Photocell Level (per Photocell)
147 +Plug Loads Enabled
148 +System:
149 +Demand Response Enabled
150 +System Wide Override (Panic/Emergency)
151 +~* More Features added upon request
152 +)))|(((
153 +Per Room Status:
154 +Online
155 +On
156 +Occupied
157 +Daylighting Active
158 +Device Battery is Low
159 +Plug Loads Enabled
160 +Occupancy Sensor Enabled
161 +Current Daylight Level
162 +Active Scene
163 +\\System:
164 +Demand Response Enabled
165 +)))|N/A
166 +|BACNET Settings Scope
167 +(What Points are Exposed)|Per Area|Global|N/A
168 +|BACNET Points Supported|Depends on Crestron License and Hardware|1000|N/A
169 +|Crestron Fusion|Y|N|N/A
170 +|Export to Zūm Floor Hub|Y, Licensed|N/A|N/A
171 +|GLPAC|Y|N|N/A
172 +|System to System Link|Y|N|N/A
173 +|Minimum ZUM-NET Firmware|(((
174 +CNET Mode: ZUM-WIRED 1.02.10 puf
175 +ZUM Mode: ZUM-WIRED 1.xx.xxx puf (Pending)
176 +)))|See Crestron, expected to be v1.01|See Crestron, expected to be v1.01
177 +|Minimum SHOWRUNNER™ Version|(((
178 +CNET Mode: 3.016
179 +ZUM Mode: TBD
180 +)))|N/A|N/A
181 +|ZWMS (Zum Wired Master/Slave Mode)|MASTER|MASTER|MASTER or SLAVE
182 +|ZWMODE|CNET or ZUM (ZUM Support Pending official release from Crestron)|ZUM|ZUM
183 +
184 +=== Caveats ===
185 +* Consult Chief Integrations to verify sequence of operations if there are any concerns.
186 +* Additional caveats:
187 +** --Occupancy status is not reported to ShowRunner when ZUMNET/ZUMLINK JBOXs come online. This has been acknowledged as a bug by Crestron in firmware v1.001.054 and v1.00.009 and is pending a fix from Crestron.-- Fixed in 1.02.010 firmware and Device Database 200.150.002, ShowRunner 3.016 has been updated with these fixes from Crestron.
188 +** --Raw Occupancy reporting does not work. A delay of 5 seconds to 5 minutes between sensor vacancy and reported vacancy to ShowRunner. ShowRunner attempts to set 30 seconds (v3.003 to v3.009) or 5 seconds (v3.010 and later) but it is not always honored. This has been acknowledged as a bug by Crestron in firmware v1.001.054 and v1.00.009 and is pending a fix from Crestron.-- Fixed in 1.02.010 firmware and Device Database 200.150.002, ShowRunner 3.016 has been updated with these fixes from Crestron.
189 +** Cresnet Discovery is not working on ZUMNET-JBOXs. Crestron has acknowledged a fix has been sent to QE. Discovery must be fixed before ShowRunner can auto-discover hardware.
190 +=== FAQ: ===
191 +* I want to have a single connection to the building and have all of my Crestron devices on the Control Subnet (same topology as a ZUM-FLOOR-HUB) and use ShowRunner™ Total Control?
192 +//Use a CP4N in lieu of the ZUM-FLOOR-HUB. A DIN-AP4 is not required. Crestron can supply a DIN-EN-6X18 with CEN-SW-POE-16 and CP4N racked in a 2RU mount plus 3 DIN rails. [[See Design Details.>>doc:Design Guide.Hardware Design Guide.Crestron Zūm Wired.Design to co-locate a CP4N and CEN-SWPOE-16 in the Same DIN-EN Cabinet.WebHome]]//
193 +* Do I need a Crestron BACnet license when using ShowRunner for BACnet integration?
194 +//If over 50 BACnet points are needed then a license (SW-3SERIES-BACNET-50+) will be needed for each Crestron processor that will provide BACnet points to the BMS.//
195 +
196 +
197 +== Out-of-the-Box vs App vs Default Program vs Custom Program ==
198 +
199 +Below is a Feature Comparison Table taken from the v3.05.02 Zūm Wired firmware release notes.
200 +
201 +(% class="table-condensed" %)
202 +|**Feature**|**Out of the Box Functionality**|(((
203 +**Zūm App**
204 +
205 +**(Standalone)**
206 +)))|(((
207 +**Networked**
208 +
209 +**(HUB4)**
210 +)))|**Custom Prog.**|**Notes**
211 +|Keypads|Scn recall / OFF|*|*|*|Affect all load controllers excluding Plug controllers
212 +|Presence detectors (Occ sensors)|Scn 1 / Scn 16|*|*|*|Presence detectors affect all load controllers
213 +|Programmable scenes| |✓|*|*|
214 +|Occupancy/Vacancy logic| |✓|*|*|
215 +|Daylight Harvesting| |✓|*|*|J-box analog input support only, ZUMLINK- Daylight sensor via custom programming only.
216 +|Customized Button Functions*
217 +(Tap/Double-Tap/ Hold)| |✓|*|*|none, Off, On, Toggle, Scene 1-16, Export button to Hub
218 +|Create a room configuration Template| |✓|*|*|
219 +|Apply room configuration template| |✓|✓| |Identical hardware rooms required
220 +|Universal 2-wire phase dimming up to 16A| |✓|*|*|ZUMLINK-EXP-DIMU support & Zūm App discovery/configuration
221 +|DALI addressing, Broadcast and groups
222 +support (Zūm Mode)| |✓|*|*|Allows control as Broadcast or 16 DALI Groups
223 +|Device Firmware updating via Zūm APP(BLE).| |✓| | |Requires primary controller at ver. 1.2.60
224 +|DALI addressing and DALI group support (CNET Mode)| | | |✓|Allows addressing, grouping and control of 16 Dali Groups using Simpl #, Simpl Windows
225 +|CNET / Zūm Mode Auto Switch| | | |✓|Automatically switches from CNET to Zum Mode when control system goes offline
226 +|Load shedding| | |✓|*|
227 +|Global/Multi/Cross-room KP| | |✓|*|Scenes, plug load and Occupancy enable/disable
228 +|Timeclock event triggers| | |✓|*|
229 +|DALI Type 6 TC| | | |✓|
230 +|DALI Type 8 TC| | | |✓|
231 +|Touch screen| | |*|✓|Hub4 support with mirror room modules
232 +|Shades| | | |✓|
233 +|AV integration| | |*|✓|Hub4 support with mirror room modules
234 +|Energy Monitoring| | | |✓|
235 +|(((
236 +Floor Map
237 +
238 +* denotes that can be used but not required to achieve functionality
239 +)))| | |*|✓|Hub4 support with mirror room modules
240 +)))
241 +
242 +