34 34  == Ease of Start-Up and Documentation ==
35 35  
36 36  Every SHOWRUNNER™ job comes with a number of Chief Tools™ to simplify the start-up process and enable Agents and Technicians to for networked Zūm Wired systems. These tools include:
37 +
37 37  * SRTakeoff spreadsheet provides the Technician with one location to view device addresses, record serial numbers, and track any issues discovered during start-up
38 38  * Zūm Wired Load Script generator enables technicians to easily create load scripts to streamline necessary configuration tasks based on the DeviceSummary.txt generated by Toolbox
39 39  
... ... @@ -58,5 +58,47 @@
58 58  
59 59  = Feature Comparison Table =
60 60  
61 -Lorem
62 +Below is a Feature Comparison Table taken from the v3.05.02 Zūm Wired firmware release notes.
63 +
64 +(% class="table-condensed" %)
65 +|**Feature**|**Out of the Box Functionality**|(((
66 +**Zūm App**
67 +
68 +**(Standalone)**
69 +)))|(((
70 +**Networked**
71 +
72 +**(HUB4)**
73 +)))|**Custom Prog.**|**Notes**
74 +|Keypads|Scn recall / OFF|*|*|*|Affect all load controllers excluding Plug controllers
75 +|Presence detectors (Occ sensors)|Scn 1 / Scn 16|*|*|*|Presence detectors affect all load controllers
76 +|Programmable scenes| |✓|*|*|
77 +|Occupancy/Vacancy logic| |✓|*|*|
78 +|Daylight Harvesting| |✓|*|*|J-box analog input support only, ZUMLINK- Daylight sensor via custom programming only.
79 +|Customized Button Functions*
80 +(Tap/Double-Tap/ Hold)| |✓|*|*|none, Off, On, Toggle, Scene 1-16, Export button to Hub
81 +|Create a room configuration Template| |✓|*|*|
82 +|Apply room configuration template| |✓|✓| |Identical hardware rooms required
83 +|Universal 2-wire phase dimming up to 16A| |✓|*|*|ZUMLINK-EXP-DIMU support & Zūm App discovery/configuration
84 +|DALI addressing, Broadcast and groups
85 +support (Zūm Mode)| |✓|*|*|Allows control as Broadcast or 16 DALI Groups
86 +|Device Firmware updating via Zūm APP(BLE).| |✓| | |Requires primary controller at ver. 1.2.60
87 +|DALI addressing and DALI group support (CNET Mode)| | | |✓|Allows addressing, grouping and control of 16 Dali Groups using Simpl #, Simpl Windows
88 +|CNET / Zūm Mode Auto Switch| | | |✓|Automatically switches from CNET to Zum Mode when control system goes offline
89 +|Load shedding| | |✓|*|
90 +|Global/Multi/Cross-room KP| | |✓|*|Scenes, plug load and Occupancy enable/disable
91 +|Timeclock event triggers| | |✓|*|
92 +|DALI Type 6 TC| | | |✓|
93 +|DALI Type 8 TC| | | |✓|
94 +|Touch screen| | |*|✓|Hub4 support with mirror room modules
95 +|Shades| | | |✓|
96 +|AV integration| | |*|✓|Hub4 support with mirror room modules
97 +|Energy Monitoring| | | |✓|
98 +|(((
99 +Floor Map
100 +
101 +* denotes that can be used but not required to achieve functionality
102 +)))| | |*|✓|Hub4 support with mirror room modules