Last modified by Alexander Mott on 2023/12/08 18:49

From version 13.1
edited by Alexander Mott
on 2023/03/27 21:45
Change comment: There is no comment for this version
To version 15.1
edited by Alexander Mott
on 2023/03/28 16:22
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -23,28 +23,23 @@
23 23  
24 24  Lorem
25 25  
26 -== Ease of Start-Up ==
26 +== Exclusive Features ==
27 27  
28 28  Lorem
29 29  
30 -- chief tools for tracking hardware information
30 +== Suitable for a Range of Applications ==
31 31  
32 -- chief tools for generating loadscripts to simplify startup
33 -
34 -== Exclusive Features ==
35 -
36 36  Lorem
37 37  
38 -== Advanced Reporting Features ==
34 +== Ease of Start-Up and Documentation ==
39 39  
40 -- see all hardware online status from one place
36 +Every SHOWRUNNER™ job comes with a number of Chief Tools™ to simplify the start-up process and enable Agents and Technicians to for networked Zūm Wired systems. These tools include:
41 41  
42 -- records of device/hardware functionality
38 +* SRTakeoff spreadsheet provides the Technician with one location to view device addresses, record serial numbers, and track any issues discovered during start-up
39 +* Zūm Wired Load Script generator enables technicians to easily create load scripts to streamline necessary configuration tasks based on the DeviceSummary.txt generated by Toolbox
43 43  
44 -== Suitable for a Range of Applications ==
41 +See the [[Starting Up Zūm Wired with SHOWRUNNER™>>doc:Design Guide.Hardware Design Guide.Crestron Zum Wired.Crestron Zum Wired Overview.WebHome||anchor="HStart-UpGuide"]] page for more information on starting up Zūm Wired systems with SHOWRUNNER™.
45 45  
46 -Lorem
47 -
48 48  == Support and Continued Development ==
49 49  
50 50  Lorem
... ... @@ -64,5 +64,47 @@
64 64  
65 65  = Feature Comparison Table =
66 66  
67 -Lorem
62 +Below is a Feature Comparison Table taken from the v3.05.02 Zūm Wired firmware release notes.
63 +
64 +(% class="table-condensed" %)
65 +|**Feature**|**Out of the Box Functionality**|(((
66 +**Zūm App**
67 +
68 +**(Standalone)**
69 +)))|(((
70 +**Networked**
71 +
72 +**(HUB4)**
73 +)))|**Custom Prog.**|**Notes**
74 +|Keypads|Scn recall / OFF|*|*|*|Affect all load controllers excluding Plug controllers
75 +|Presence detectors (Occ sensors)|Scn 1 / Scn 16|*|*|*|Presence detectors affect all load controllers
76 +|Programmable scenes| |✓|*|*|
77 +|Occupancy/Vacancy logic| |✓|*|*|
78 +|Daylight Harvesting| |✓|*|*|J-box analog input support only, ZUMLINK- Daylight sensor via custom programming only.
79 +|Customized Button Functions*
80 +(Tap/Double-Tap/ Hold)| |✓|*|*|none, Off, On, Toggle, Scene 1-16, Export button to Hub
81 +|Create a room configuration Template| |✓|*|*|
82 +|Apply room configuration template| |✓|✓| |Identical hardware rooms required
83 +|Universal 2-wire phase dimming up to 16A| |✓|*|*|ZUMLINK-EXP-DIMU support & Zūm App discovery/configuration
84 +|DALI addressing, Broadcast and groups
85 +support (Zūm Mode)| |✓|*|*|Allows control as Broadcast or 16 DALI Groups
86 +|Device Firmware updating via Zūm APP(BLE).| |✓| | |Requires primary controller at ver. 1.2.60
87 +|DALI addressing and DALI group support (CNET Mode)| | | |✓|Allows addressing, grouping and control of 16 Dali Groups using Simpl #, Simpl Windows
88 +|CNET / Zūm Mode Auto Switch| | | |✓|Automatically switches from CNET to Zum Mode when control system goes offline
89 +|Load shedding| | |✓|*|
90 +|Global/Multi/Cross-room KP| | |✓|*|Scenes, plug load and Occupancy enable/disable
91 +|Timeclock event triggers| | |✓|*|
92 +|DALI Type 6 TC| | | |✓|
93 +|DALI Type 8 TC| | | |✓|
94 +|Touch screen| | |*|✓|Hub4 support with mirror room modules
95 +|Shades| | | |✓|
96 +|AV integration| | |*|✓|Hub4 support with mirror room modules
97 +|Energy Monitoring| | | |✓|
98 +|(((
99 +Floor Map
100 +
101 +* denotes that can be used but not required to achieve functionality
102 +)))| | |*|✓|Hub4 support with mirror room modules
68 68  )))
104 +
105 +