Changes for page **Crestron Zūm Wired and SHOWRUNNER™
Last modified by Alexander Mott on 2023/12/08 18:49
From version 10.1
edited by Alexander Mott
on 2023/03/24 18:12
on 2023/03/24 18:12
Change comment:
There is no comment for this version
To version 22.1
edited by Alexander Mott
on 2023/12/08 18:49
on 2023/12/08 18:49
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -*Crestron Zūm Wired and SHOWRUNNER™ 1 +**Crestron Zūm Wired and SHOWRUNNER™ - Content
-
... ... @@ -1,3 +1,8 @@ 1 +(% class="box successmessage" %) 2 +((( 3 +Page for showrunner feature comparison, reasons for using showrunner, etc.; should also include information from old 4 +))) 5 + 1 1 (% class="box errormessage" %) 2 2 ((( 3 3 n/a ... ... @@ -8,10 +8,12 @@ 8 8 n/a 9 9 ))) 10 10 16 +{{box cssClass="floatinginfobox" title="**CONTENTS**"}} 17 +{{toc/}} 18 +{{/box}} 19 + 11 11 (% class="row" %) 12 12 ((( 13 -(% class="col-xs-12 col-sm-8" %) 14 -((( 15 15 Lorem 16 16 17 17 See //[[Figure 1>>WebHome||anchor="HFigure1"]]// for details. ... ... @@ -21,11 +21,6 @@ 21 21 22 22 Lorem 23 23 24 -== Ease of Start-Up == 25 - 26 - 27 -Lorem 28 - 29 29 == Exclusive Features == 30 30 31 31 Lorem ... ... @@ -34,32 +34,214 @@ 34 34 35 35 Lorem 36 36 39 +== Ease of Start-Up and Documentation == 40 + 41 +Every SHOWRUNNER™ job comes with a number of Chief Tools™ to simplify the start-up process and enable Agents and Technicians to for networked Zūm Wired systems. These tools include: 42 + 43 +* SRTakeoff spreadsheet provides the Technician with one location to view device addresses, record serial numbers, and track any issues discovered during start-up 44 +* Zūm Wired Load Script generator enables technicians to easily create load scripts to streamline necessary configuration tasks based on the DeviceSummary.txt generated by Toolbox 45 + 46 +See the [[Starting Up Zūm Wired with SHOWRUNNER™>>doc:Design Guide.Hardware Design Guide.Crestron Zum Wired.Crestron Zum Wired Overview.WebHome||anchor="HStart-UpGuide"]] page for more information on starting up Zūm Wired systems with SHOWRUNNER™. 47 + 37 37 == Support and Continued Development == 38 38 39 39 Lorem 40 40 41 -= FeatureComparisonTable=52 += Best Practices for Zūm Wired with SHOWRUNNER™ = 42 42 43 -Lorem 44 -))) 54 +Though it is possible to design a Zūm Wired system to use the standard ZUM-HUB4 program and then import rooms from SHOWRUNNER™, it is not recommended as it adds the expense of a custom program without taking advantage of any of the added functionality that SHOWRUNNER™ has to offer. 45 45 56 +Instead, to take full advantage of everything that SHOWRUNNER™ has to offer, follow these best practices: 46 46 47 -(% class="col-xs-12 col-sm-4" %) 48 -((( 49 -{{box title="**CONTENTS**"}} 50 -{{toc/}} 51 -{{/box}} 58 +* Design the system to use SHOWRUNNER™ as the main program 59 +* Set ZUMNET-JBOX-* devices in CNET mode after any App-specific configurations have been made 52 52 53 -(% class="wikigeneratedid" id="HFigure1" %) 61 +Zūm 62 + 63 +SHOWRUNNER™ 64 + 65 += Feature Comparison Tables = 66 + 67 +== SHOWRUNNER™ vs Default Program vs Standalone == 68 + 69 +(% class="box errormessage" %) 54 54 ((( 55 -[[image:Templates.Article.Template.WebHome@image1.jpg]] 56 -//Figure 1: [[Sea>>https://commons.wikimedia.org/wiki/File:Isle_of_Icacos_II.jpg]]// 71 +need to verify information is up to date for this section 57 57 ))) 58 58 59 -(% class="wikigeneratedid" id="HFigure2" %) 60 -((( 61 -[[image:Templates.Article.Template.WebHome@image2.jpg]] 62 -//Figure 2: [[Waves>>https://commons.wikimedia.org/wiki/File:Culebra_-_Playa_de_Flamenco.jpg]]// 74 +The below table compares some SHOWRUNNER exclusive features against networked systems using the default program and standalone systems using Zūm App mode. 75 + 76 +|=Feature|=((( 77 +**Networked** 78 + 79 +**(**SHOWRUNNER™**)** 80 +)))|=((( 81 +**Networked** 82 + 83 +**(HUB4)** 84 +)))|=((( 85 +**Zūm App** 86 + 87 +**(Standalone)** 63 63 ))) 89 +|(% colspan="4" %)**Hardware Requirements** 90 +|Requires ZUMNET-JBOX-*|Y|Y|N 91 +|Requires 3 or 4-Series Control System|Y (Can use a number of different 3 and 4-Series processors)|Y (Requires ZUM-HUB4)|N 92 +|Requires Physical Presence in Room to Change Scenes|N|TBD|Y 93 +|Maximum Rooms|TBD|1000|N/A 94 +|(% colspan="4" %)**User Interfaces** 95 +|Web Browser|((( 96 +Crestron SmartGraphics XPanel 97 +HTML5 UI 98 +)))|HTML5 UI|N 99 +|iOS/Android|Y, Crestron App (Paid Upgrade) or HTML5 UI (Device Web Browser)|N|Y* 100 +|Touchscreens (Crestron TSW series)|Y|N|N 101 +|(% colspan="4" %)**Features** 102 +|Scene Recall|Y|Y|Y 103 +|Override Fade Time for Scene Recall|Y|TBD|TBD 104 +|Scene Save|Y|TBD|Y 105 +|Load Control|Y|TBD|Y 106 +|Demand Response|Y|Y|N 107 +|Enable/Disable Occupancy|Y|Y|Y 108 +|Override Occupancy Logic|Y|TBD|N 109 +|Override|Y|TBD|N/A 110 +|Plug Load On/Off|Y|Y|By Hardware 111 +|Integration with Non-Zūm Crestron Hardware|Y|N|N 112 +|Custom Zūm Keypad Programming|Y|TBD|Y, within the limits of the hardware 113 +|New Feature Release Cycle|Aggressive|6-12 months|6-12 months 114 +|Room Organization|((( 115 +Organize According to Defined Nodes, multiple levels 116 +Categorization to Filter by Tag 117 +)))|Category/Room|((( 118 +N/A 64 64 ))) 120 +|Room Discovery|Automatic Discovery of ZUMNET and ZUMLINK devices (Pending)|Automatic Discovery of ZUMNET and ZUMLINK devices|N/A 121 +|Network Topology|((( 122 +* Flat 123 +* Single Handoff to LAN w/ Control Subnet 124 +(Requires CP4N/AV4/PRO4) 125 +)))|Single Handoff to LAN w/ Control Subnet|N/A 126 +|Network Addressing|((( 127 +* Manual 128 +* Customer (DHCP or Manual) 129 +* DHCP: Control Subnet (Requires CP4N/AV4/PRO4) 130 +)))|Control Subnet|N/A 131 +|Firmware Updates|PUF Tool 132 +Automatic Support on Roadmap|Automatic, Internet Connection Required|N/A 133 +|Floorplans|Y|N|N/A 134 +|(% colspan="4" %)**Calendar/Scheduling** 135 +|Logic Type|Event Driven 136 +Profile Support (Under Development)|Pattern assigned to Category|N/A 137 +|Astronomical Clock|Y|Y, Per Category|N/A 138 +|Holidays|Pattern|Hard Coded|N/A 139 +|Custom Patterns|Y, Advanced Scheduler License|N|N/A 140 +|(% colspan="4" %)**Integrations** 141 +|A/V Integration: API|Y|Limited|N/A 142 +|A/V Integration: Crestron EISC|Y|N|N/A 143 +|A/V Integration: RS-232|Y|TBD|N/A 144 +|BACNET|Y, SHOWRUNNER™ and Crestron Licenses Needed|Y|N/A 145 +|BACNET Features|((( 146 +Per Area Status: 147 +Active Scene 148 +Occupied 149 +Occupancy Enabled 150 +Individual Load Level 151 +Photocell Level (per Photocell) 152 +Plug Loads Enabled 153 +System: 154 +Demand Response Enabled 155 +System Wide Override (Panic/Emergency) 156 +~* More Features added upon request 157 +)))|((( 158 +Per Room Status: 159 +Online 160 +On 161 +Occupied 162 +Daylighting Active 163 +Device Battery is Low 164 +Plug Loads Enabled 165 +Occupancy Sensor Enabled 166 +Current Daylight Level 167 +Active Scene 168 +\\System: 169 +Demand Response Enabled 170 +)))|N/A 171 +|BACNET Settings Scope 172 +(What Points are Exposed)|Per Area|Global|N/A 173 +|BACNET Points Supported|Depends on Crestron License and Hardware|1000|N/A 174 +|Crestron Fusion|Y|N|N/A 175 +|Export to Zūm Floor Hub|Y, Licensed|N/A|N/A 176 +|GLPAC|Y|N|N/A 177 +|System to System Link|Y|N|N/A 178 +|Minimum ZUM-NET Firmware|((( 179 +CNET Mode: ZUM-WIRED 1.02.10 puf 180 +ZUM Mode: ZUM-WIRED 1.xx.xxx puf (Pending) 181 +)))|See Crestron, expected to be v1.01|See Crestron, expected to be v1.01 182 +|Minimum SHOWRUNNER™ Version|((( 183 +CNET Mode: 3.016 184 +ZUM Mode: TBD 185 +)))|N/A|N/A 186 +|ZWMS (Zum Wired Master/Slave Mode)|MASTER|MASTER|MASTER or SLAVE 187 +|ZWMODE|CNET or ZUM (ZUM Support Pending official release from Crestron)|ZUM|ZUM 188 + 189 +=== Caveats === 190 + 191 +* Consult Chief Integrations to verify sequence of operations if there are any concerns. 192 +* Additional caveats: 193 +** --Occupancy status is not reported to ShowRunner when ZUMNET/ZUMLINK JBOXs come online. This has been acknowledged as a bug by Crestron in firmware v1.001.054 and v1.00.009 and is pending a fix from Crestron.-- Fixed in 1.02.010 firmware and Device Database 200.150.002, ShowRunner 3.016 has been updated with these fixes from Crestron. 194 +** --Raw Occupancy reporting does not work. A delay of 5 seconds to 5 minutes between sensor vacancy and reported vacancy to ShowRunner. ShowRunner attempts to set 30 seconds (v3.003 to v3.009) or 5 seconds (v3.010 and later) but it is not always honored. This has been acknowledged as a bug by Crestron in firmware v1.001.054 and v1.00.009 and is pending a fix from Crestron.-- Fixed in 1.02.010 firmware and Device Database 200.150.002, ShowRunner 3.016 has been updated with these fixes from Crestron. 195 +** Cresnet Discovery is not working on ZUMNET-JBOXs. Crestron has acknowledged a fix has been sent to QE. Discovery must be fixed before ShowRunner can auto-discover hardware. 196 + 197 +=== FAQ: === 198 + 199 +* I want to have a single connection to the building and have all of my Crestron devices on the Control Subnet (same topology as a ZUM-FLOOR-HUB) and use ShowRunner™ Total Control? 200 +//Use a CP4N in lieu of the ZUM-FLOOR-HUB. A DIN-AP4 is not required. Crestron can supply a DIN-EN-6X18 with CEN-SW-POE-16 and CP4N racked in a 2RU mount plus 3 DIN rails. [[See Design Details.>>doc:Design Guide.Hardware Design Guide.Crestron Zūm Wired.Design to co-locate a CP4N and CEN-SWPOE-16 in the Same DIN-EN Cabinet.WebHome]]// 201 +* Do I need a Crestron BACnet license when using ShowRunner for BACnet integration? 202 +//If over 50 BACnet points are needed then a license (SW-3SERIES-BACNET-50+) will be needed for each Crestron processor that will provide BACnet points to the BMS.// 203 + 204 +== Out-of-the-Box vs App vs Default Program vs Custom Program == 205 + 206 +Below is a Feature Comparison Table taken from the v3.05.02 Zūm Wired firmware release notes. 207 + 208 +(% class="table-condensed" %) 209 +|**Feature**|**Out of the Box Functionality**|((( 210 +**Zūm App** 211 + 212 +**(Standalone)** 213 +)))|((( 214 +**Networked** 215 + 216 +**(HUB4)** 217 +)))|**Custom Prog.**|**Notes** 218 +|Keypads|Scn recall / OFF|*|*|*|Affect all load controllers excluding Plug controllers 219 +|Presence detectors (Occ sensors)|Scn 1 / Scn 16|*|*|*|Presence detectors affect all load controllers 220 +|Programmable scenes| |✓|*|*| 221 +|Occupancy/Vacancy logic| |✓|*|*| 222 +|Daylight Harvesting| |✓|*|*|J-box analog input support only, ZUMLINK- Daylight sensor via custom programming only. 223 +|Customized Button Functions* 224 +(Tap/Double-Tap/ Hold)| |✓|*|*|none, Off, On, Toggle, Scene 1-16, Export button to Hub 225 +|Create a room configuration Template| |✓|*|*| 226 +|Apply room configuration template| |✓|✓| |Identical hardware rooms required 227 +|Universal 2-wire phase dimming up to 16A| |✓|*|*|ZUMLINK-EXP-DIMU support & Zūm App discovery/configuration 228 +|DALI addressing, Broadcast and groups 229 +support (Zūm Mode)| |✓|*|*|Allows control as Broadcast or 16 DALI Groups 230 +|Device Firmware updating via Zūm APP(BLE).| |✓| | |Requires primary controller at ver. 1.2.60 231 +|DALI addressing and DALI group support (CNET Mode)| | | |✓|Allows addressing, grouping and control of 16 Dali Groups using Simpl #, Simpl Windows 232 +|CNET / Zūm Mode Auto Switch| | | |✓|Automatically switches from CNET to Zum Mode when control system goes offline 233 +|Load shedding| | |✓|*| 234 +|Global/Multi/Cross-room KP| | |✓|*|Scenes, plug load and Occupancy enable/disable 235 +|Timeclock event triggers| | |✓|*| 236 +|DALI Type 6 TC| | | |✓| 237 +|DALI Type 8 TC| | | |✓| 238 +|Touch screen| | |*|✓|Hub4 support with mirror room modules 239 +|Shades| | | |✓| 240 +|AV integration| | |*|✓|Hub4 support with mirror room modules 241 +|Energy Monitoring| | | |✓| 242 +|((( 243 +Floor Map 244 + 245 +* denotes that can be used but not required to achieve functionality 246 +)))| | |*|✓|Hub4 support with mirror room modules 65 65 ))) 248 + 249 +